Delta Amplon RT Series UPS, 3-phase, 15kVAA total solution for reliable power with high availability and performance The Amplon RT Series 5 20kVA is an online double conversion UPS that provides best in class designs in compact 2U size, high power density, system efficiency, and versatile configurations to fulfill customers' requirements. Unity output power factor maximizes capacity for more critical loads, while outstanding energy savings can be achieved based on the AC AC efficiency of up
A total solution for reliable power with high availability and performance
The Amplon RT Series 5-20kVA is an online double-conversion UPS that provides best-in-class designs in compact 2U size, high power density, system efficiency, and versatile configurations to fulfill customers' requirements. Unity output power factor maximizes capacity for more critical loads, while outstanding energy savings can be achieved based on the AC-AC efficiency of up to 96.5% and 99% in ECO mode. In addition, RT Series 5-20kVA UPS is the first in the market that offers standard Li-ion external battery cabinets, which deliver better power density and sustainability. Along with the parallel capacity of up to four units, the new series is the ideal small power UPS for mission-critical applications, such as servers, data centers, telecommunications, and manufacturing.
| Amplon Family, RT Series 6/8/10 kVA Single Phase, 15/20 kVA Three Phase Features: • True online double-conversion topology and zero transfer time to battery provides 24/7 full-time protection • Unity output power factor guarantees no de-rating with loads and provides permanent 100% kW • Best-in-class AC-AC efficiency of up to 96.5% and 99% in ECO mode lowers energy costs • Automatic fan speed control maximizes system efficiency and significantly reduces audible noise and prolongs battery life • Fan failure detection sends early warnings to facilitate predictive maintenance of UPS • Programmable load bank disconnects non-critical loads when a blackout occurs and reserves more battery power for critical loads • Up to four unit’s parallel capacity allows redundancy and load expansion • Hot swappable batteries ensure continuous operation even when batteries are being replaced • VRLA and Li-ion External Battery Cabinet (EBC) are available for scalable runtime • The Maintenance Bypass Breaker (MBB) is optional for easy UPS replacement without powering down critical systems • The RRPP (Rack Remote Power Panel), which can be integrated with standard server racks, simplifies power output distribution and power monitoring • Common battery configuration is supported in UPS parallel mode to save installation space and additional battery Technical Specification Product Code UPS602R2RT0B035 UPS802R2RT0B035 UPS103R2RT0B035 UPS153R6RT2N053 UPS203R6RT2N053 Power Rating 6kVA/6kW 8kVA/8kW 10kVA/10kW 15kVA/15kW 20kVA/20kW Input Voltage Range 100 ~ 280V (Single phase, 2-wire + G) 100 ~ 175V with linear de-rating 50 ~ 100% 138 ~ 485V (Three phase, 4-wire + G) 138 ~ 305V with linear de-rating 40 ~ 100% Input Frequency 40 ~ 70 Hz Input Power Factor > 0.99 (full load) Output Power Factor Unity Output Voltage 200, 208, 220, 230, 240 Vac (Single phase) 380/400/415 Vac (Three phase), or 220/230/240 Vac (Single phase) Output Frequency 50/60Hz ±0.05Hz Output Voltage Harmonic Distortion ≤ 2% (linear load) Efficiency AC-AC Up to 95.5% Up to 96.5% Efficiency ECO Mode Up to 99% Battery Voltage Standard Runtime Model 192 Vdc 192 Vdc 240 Vdc 240 Vdc ±144 Vdc*, ±192 ~ 264 Vdc Charger Current Standard Runtime Model 1A (default) 1.5A (default) Extended Runtime Model Up to 8A Up to 8A Audible Noise 48 dB 50 dB 54 dB Display Graphical and multi-lingual LCD Communication Interfaces MINI Slot x 1, Parallel Port** x 2, USB Port x 1, RS232 Port*** x 1, RS485 Port x 1, REPO/ROO Port x 1, Dry Contact x 4 Standard Runtime Model Dimensions (W x D x H) 440 x 665 x 176 mm 440 x 750 x 218 mm Extended Runtime Model Dimensions (W x D x H) 440 x 430 x 88.2 mm 440 x 565 x 88.2 mm 440 x 730 x 88.2 mm Environment Operating Temperature 0 ~ 55° C**** Relative Humidity 5 ~ 95% (non-condensing) *De-rating to 70% load ** Only applicable to RT 5-10kVA Extended Runtime Model and RT 15/20kVA *** Not applicable to RT 20kVA **** When the operating temperature is at 40 ~ 55° C, the UPS will be de-rated to 75% of its capacity All specifications are subject to change without prior notice. |
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy